LIB Industry designs and manufactures walk in chambers including integrated type and disassembling type.With large volume, the chamber can be used to simulate the single or complicated environmental factors in the atmosphere such as temperature, humidity, salt fog, illumination, dust, rain and vibration.
These Walk-in Test Chambers comply with a wide range of international and industry standards, including IEC 60068, ISO 16750, ASTM D2247, MIL-STD-810, JIS C 60068, SAE J1211, EN 60068-3-11, GB/T 2423, UL 199/UL 852, and more. This broad standards coverage ensures that tests meet regulatory requirements across automotive, aerospace, electronics, and materials industries, making LIB walk-in chambers a versatile solution for multi-environment testing.
WTH-0015C
LIB Industry
| Availability: | |
|---|---|
| Quantity: | |
This walk-in environmental chamber provides temperature and humidity testing for large components and equipment. Many standard and custom walk-in, drive-in chambers for your needs.
Advantages
1. Massive Testing Capacity: With volumes ranging from 3 m³ to 100 m³, LIB walk-in chambers accommodate large components, high-volume batches, or multiple sample racks at once. This spacious interior allows simultaneous testing of multiple items under uniform conditions, reducing cycle time and increasing laboratory throughput.
2. Precise Environmental Control: Advanced PT-100 Class A sensors and PID-controlled systems maintain temperature within ±0.5 °C and humidity within ±2.5 % RH, while optimized airflow ensures even distribution. Every sample experiences consistent environmental exposure, delivering reliable and repeatable results for complex cycles.
3. Multi-Factor Simulation: These chambers can replicate a variety of real-world environmental stresses, including extreme temperatures (–70 °C to +150 °C), high humidity (20 %–98 % RH), salt fog, illumination, dust, rain, and vibration. This versatility supports testing across automotive, aerospace, electronics, and materials applications.
4. Energy-Efficient Operation: With thick insulation, water-recycling humidification, and intelligent energy-saving algorithms, LIB chambers minimize electricity and water usage. Automated low-water alarms and refill systems ensure uninterrupted testing while reducing operational costs and environmental impact.
5. User-Friendly and Safe: A multilingual touchscreen interface allows intuitive program setup, monitoring, and data logging, while Ethernet/USB connectivity enables seamless integration with LIMS. Safety features include over-temperature, over-pressure, and low-water protections, and corrosion-resistant SUS304 interiors ensure long-term durability with minimal maintenance.
Technical Parameters
| Model | WTH-0015C |
| Internal dimension (mm) | 2500*2500*2500 D*W*H |
| Overall dimension (mm) | 4000*2550*2850 D*W*H |
| Temperature range | -60℃ ~ +150℃ |
| Humidity range | 20% ~ 95% RH |
| Temperature fluctuations | ± 2.0℃ |
| Humidity fluctuations | ± 5.0% RH |
| Heating rate | 1℃ / min |
| Cooling rate | 1 ℃ / min |
| Controller | Programmable color LCD touch screen controller; Ethernet port |
| Cooling system | Mechanical compression refrigeration system |
| Safety device | Humidifier dry-combustion protection; over-temperature protection; over-current protection; Refrigerant high-pressure protection; Water shortage protection; Earth leakage protection |
| Exterior material | Steel Plate with protective coating |
| Interior material | SUS304stainlesssteel |
Operate Guide of the Walk-in Test Chamber
To operate the LIB Walk-In Temperature and Humidity Chamber, first ensure the chamber is properly leveled and connected to power and water supplies. Load your samples securely on the adjustable racks or tracks, then program the desired environmental conditions—temperature (–70 °C to +150 °C), humidity (20 %–98 % RH), and cycle duration—using the touchscreen PID controller. The system automatically manages airflow, heating, and cooling, and continuously monitors temperature and humidity with PT 100 Class A sensors, maintaining stability within ±0.5 °C and ±2.5 % RH. Data can be logged in real time and exported via USB or Ethernet. After the test, safely remove samples and perform routine cleaning and maintenance to ensure long-term chamber performance.
Video of the Walk-in Test Chambers
Trusted Worldwide Assistance
LIB delivers peace of mind with a 3-year warranty and lifetime technical support. In the unlikely event that an issue cannot be fixed remotely, we will promptly provide a replacement chamber at no extra charge. Our skilled English-speaking support team is available around the clock to assist customers globally. Essential spare parts are stocked in international hubs for rapid delivery within 7–15 days, and comprehensive guidance ensures safe transportation, setup, and operation of your equipment.
This walk-in environmental chamber provides temperature and humidity testing for large components and equipment. Many standard and custom walk-in, drive-in chambers for your needs.
Advantages
1. Massive Testing Capacity: With volumes ranging from 3 m³ to 100 m³, LIB walk-in chambers accommodate large components, high-volume batches, or multiple sample racks at once. This spacious interior allows simultaneous testing of multiple items under uniform conditions, reducing cycle time and increasing laboratory throughput.
2. Precise Environmental Control: Advanced PT-100 Class A sensors and PID-controlled systems maintain temperature within ±0.5 °C and humidity within ±2.5 % RH, while optimized airflow ensures even distribution. Every sample experiences consistent environmental exposure, delivering reliable and repeatable results for complex cycles.
3. Multi-Factor Simulation: These chambers can replicate a variety of real-world environmental stresses, including extreme temperatures (–70 °C to +150 °C), high humidity (20 %–98 % RH), salt fog, illumination, dust, rain, and vibration. This versatility supports testing across automotive, aerospace, electronics, and materials applications.
4. Energy-Efficient Operation: With thick insulation, water-recycling humidification, and intelligent energy-saving algorithms, LIB chambers minimize electricity and water usage. Automated low-water alarms and refill systems ensure uninterrupted testing while reducing operational costs and environmental impact.
5. User-Friendly and Safe: A multilingual touchscreen interface allows intuitive program setup, monitoring, and data logging, while Ethernet/USB connectivity enables seamless integration with LIMS. Safety features include over-temperature, over-pressure, and low-water protections, and corrosion-resistant SUS304 interiors ensure long-term durability with minimal maintenance.
Technical Parameters
| Model | WTH-0015C |
| Internal dimension (mm) | 2500*2500*2500 D*W*H |
| Overall dimension (mm) | 4000*2550*2850 D*W*H |
| Temperature range | -60℃ ~ +150℃ |
| Humidity range | 20% ~ 95% RH |
| Temperature fluctuations | ± 2.0℃ |
| Humidity fluctuations | ± 5.0% RH |
| Heating rate | 1℃ / min |
| Cooling rate | 1 ℃ / min |
| Controller | Programmable color LCD touch screen controller; Ethernet port |
| Cooling system | Mechanical compression refrigeration system |
| Safety device | Humidifier dry-combustion protection; over-temperature protection; over-current protection; Refrigerant high-pressure protection; Water shortage protection; Earth leakage protection |
| Exterior material | Steel Plate with protective coating |
| Interior material | SUS304stainlesssteel |
Operate Guide of the Walk-in Test Chamber
To operate the LIB Walk-In Temperature and Humidity Chamber, first ensure the chamber is properly leveled and connected to power and water supplies. Load your samples securely on the adjustable racks or tracks, then program the desired environmental conditions—temperature (–70 °C to +150 °C), humidity (20 %–98 % RH), and cycle duration—using the touchscreen PID controller. The system automatically manages airflow, heating, and cooling, and continuously monitors temperature and humidity with PT 100 Class A sensors, maintaining stability within ±0.5 °C and ±2.5 % RH. Data can be logged in real time and exported via USB or Ethernet. After the test, safely remove samples and perform routine cleaning and maintenance to ensure long-term chamber performance.
Video of the Walk-in Test Chambers
Trusted Worldwide Assistance
LIB delivers peace of mind with a 3-year warranty and lifetime technical support. In the unlikely event that an issue cannot be fixed remotely, we will promptly provide a replacement chamber at no extra charge. Our skilled English-speaking support team is available around the clock to assist customers globally. Essential spare parts are stocked in international hubs for rapid delivery within 7–15 days, and comprehensive guidance ensures safe transportation, setup, and operation of your equipment.