TH-50/ TH-80
LIB Industry
| Availability: | |
|---|---|
| Quantity: | |
Shelf-life data takes weeks or months to collect, and a drifting storage condition can ruin all of it. The LIB Industry Small Benchtop Storage Temperature Cabinet keeps your food samples in a steady, documented environment throughout the study. You can run refrigerated storage at 4°C, room-temperature storage at 20–25°C, and accelerated aging at 30°C, 37°C, or 40°C under controlled humidity. For frozen products, you can also set lower temperatures such as -18°C or -20°C and perform freeze-thaw cycling to simulate cold-chain interruptions. These tests help you identify moisture pickup, clumping, softening, oxidation, color fading, and packaging leaks before your product reaches the shelf. Because it is compact and quiet, the cabinet can stand next to the balance, texture analyzer, or sample-preparation station. You do not need a separate chamber room or need to carry samples across the building.
Where Small Benchtop Storage Temperature Cabinet Fits in Your Food Lab
Shelf-life studies
(25 °C / 60% RH , 37–40 °C / 75% RH)
Dairy and drinks (Typically 4 °C to 40 °C)
Frozen and chilled goods (Typically -40 °C to +4 °C)
Food Supplements and Ingredients (ICH Q1A; typically 25 °C / 60% RH)
Food Packaging
(ASTM D4332, ISO 187, 23 °C / 50% RH)
Food Research & QA
(Customer-specific procedures)
1. A full storage plan in one test chamber: Without switching equipment, you can move from a refrigerator-style hold to a warm, humid accelerated test, then on to a freeze-thaw trial. Build the whole sequence on the controller and let it run unattended overnight or over a weekend.
2. Conditions you can trust: Temperature holds within ±0.5 °C and humidity within ±2.5% RH. PT100 Class A sensors read the chamber air, and the PID controller adjusts continuously. Stable conditions mean differences between sample groups come from the food, not from the equipment.
3. Even exposure on every shelf: Air flows through the chamber in alternating directions, which keeps hot, cold, wet, and dry pockets from forming. A sample at the back corner gets the same treatment as one near the door.
4. Built for a food lab: The interior is SUS304 stainless steel, which tolerates humidity and wipes clean between batches. The outside is powder-coated A3 steel that handles spills and routine cleaning. A recirculating water loop cuts down on manual refilling.
5. Simple to program, easy to document: The 7-inch color touchscreen lets you set up cycles in minutes. Ethernet and USB connections let you log data in real time and export a report in one click for your quality files.
6. Several layers of protection: The cabinet protects against humidifier dry-burning, over-temperature, over-current, high refrigerant pressure, water shortage, and earth leakage. A long-running study has a much lower risk of ending in a failed run.
| Model | TH-50 | TH-80 |
| Internal Dimension (mm) | 320*350*450 | 400*400*500 |
| Overall Dimension (mm) | 820*1160*950 | 900*1210*1000 |
| Interior Volume | 50L | 80L |
| Heat load | 1000W | |
| Temperature Range | A : -20℃ ~ +150 ℃ | |
| B : -40℃ ~ +150 ℃ | ||
| C: -70℃ ~ +150 ℃ | ||
| Temperature Fluctuation | ± 0.5 ℃ | |
| Temperature Deviation | ± 2.0 ℃ | |
| Humidity Range | 20% ~ 98% RH | |
| Humidity Deviation | ± 2.5% RH | |
| Cooling Rate | 1 ℃ / min | |
| Heating Rate | 3 ℃ / min | |
| Cooling system | Mechanical compression refrigeration system | |
| Controller | Programmable color LCD touch screen controller | |
| Ethernet connection | ||
| Safety Device | Humidifier Dry-combustion protection; Over-temperature Protection; Over-current Protection; | |
| Refrigerant High-pressure protection; Water Shortage Protection; Earth leakage Protection | ||
| Exterior Material | Steel Plate with protective coating | |
| Interior Material | SUS304 stainless steel | |
| Thermal Insulation | Polyurethane foam and insulation cotton | |
| Observation Window | Interior lighting, double-layer thermo stability silicone rubber sealing | |
| Standard Configuration | 1 Cable hole (Φ 50,) with plug; 2 shelves | |
| Weight | 190kgs | |
Q1: Can one cabinet handle both chilled storage and accelerated aging?
A: Yes. Even the Type A model covers refrigerated holds, room-temperature storage, and hot, humid accelerated conditions. Types B and C also reach deep-freeze temperatures for frozen products.
Q2: Can I simulate a cold-chain break?
A: Yes. Build a program that holds the samples cold, raises the temperature for a set period, and returns them to cold storage. You can repeat the loop as many times as the plan requires.
Q3: How is accuracy verified before shipping?
A: Every test chamber is calibrated at the factory. Nine temperature probes are placed throughout the chamber, and their average readings are compared with the reference standard. Humidity is calibrated using the dry/wet bulb method.
Founded in 2012, LIB Industry builds environmental test chambers for customers in more than 60 countries, supported by 29 distributors and 4 overseas service centers. Every test chamber carries a 3-year warranty and lifetime maintenance. Our test chambers are used by CERN, Apple, Mercedes-Benz, BYD, Siemens Gamesa, Nidec, and the University of Sydney, and many of these customers have ordered again.