LIB Industry
| Availability: | |
|---|---|
| Quantity: | |
Unlike ordinary gauze, which often contains residual oils and inconsistent fiber density, the LIB Industry wet wick undergoes controlled processing to achieve a tightly woven, high-density cotton structure. This design allows moisture to spread evenly across the fabric within seconds of contact, forming a stable evaporation film around the sensor probe. The wick resists premature hardening and mineral buildup even under continuous operation, helping laboratories avoid humidity drift and measurement instability. Produced by Xi'an LIB Industry Environmental Simulation, located at No.6 Zhangba 1st Road, Xi'an, China, the wick is manufactured under strict quality control to ensure batch-to-batch consistency for demanding laboratory environments.
Key Advantages of the Wet Bulb Gauze Wick for Humidity Climate Chambers
1. High-Density Cotton Construction: The wick's high-density cotton weave provides superior capillary action compared to standard gauze materials. This ensures water is drawn continuously and evenly from the reservoir to the sensor, preventing dry spots that could cause inaccurate humidity readings.
2. Hydrophilicity Above 95%: With a hydrophilicity rating exceeding 95%, the wick absorbs and retains moisture rapidly, forming a stable, uniform evaporation surface almost immediately after installation. This directly supports the accuracy of wet-bulb temperature measurement and, by extension, relative humidity calculation.
3. Consistent Long-Term Performance: The dense cotton fibers resist yellowing, hardening, and structural breakdown during extended testing cycles, maintaining reliable wicking performance throughout its service life before replacement is needed.
3. Contaminant-Free Composition: Manufactured without fluorescent brighteners or chemical bleaching agents, the wick minimizes the risk of chemical residue interfering with sensor accuracy or corroding metal probe surfaces.
4. Simple Installation and Maintenance: The wick is designed for straightforward installation—wrapped tightly around the sensor probe with the lower section submerged in the water reservoir—making routine replacement quick and requiring minimal technician training.
Parameters of the Wet Bulb Gauze Wick for Humidity Climate Chambers
| Name | Humidity Sensor Wet Wick |
| Size | W43 × L4000 mm/reel/box |
| Material | High-Density Cotton |
| Hydrophilicity | >95% |
| Packing | Inner - Plastic Bag; Outer - Standard Carton Box |
| Range of Application | Temperature Humidity Test Chamber, Humidity Test Device |
| Manufacturer | Xi'an LIB Industry Environmental Simulation |
| Replacement Cycle | Approximately once per month |
Applications and Testing Standards
The LIB Industry Humidity Sensor Wet Wick is widely used across industries that rely on precise environmental simulation. In electronics manufacturing, it supports humidity and damp heat testing under standards such as IEC 60068-2-78 (damp heat, steady state) and IEC 60068-2-30 (damp heat, cyclic), where chambers commonly hold conditions around 40°C to 85°C at 85% to 95% RH for 24 to 1000 hours depending on product qualification requirements. In automotive electronics testing, the wick supports humidity cycling under ISO 16750-4 and other standard, where components are cycled between 25°C and 65°C at 93% to 98% RH. Pharmaceutical stability testing following ICH Q1A(R2) typically maintains 25°C at 60% RH or 40°C at 75% RH over extended storage periods, relying on stable wet-bulb readings to confirm chamber accuracy. Meteorological and calibration applications often follow the standard, which specifies wet-bulb gauze requirements for psychrometric humidity measurement in weather instrumentation. Aerospace and defense testing under MIL-STD-810H similarly depends on consistent wet-bulb performance for humidity conditioning tests ranging from 30% to 95% RH. Across all these applications, the wick's consistent wicking behavior directly affects whether a chamber can maintain humidity tolerances typically specified at ±2% to ±3% RH.
User Guide for Humidity Sensor Wet Wick
1. Hand Hygiene Before Installation: Ensure hands are clean and free of oils, lotions, or residue before handling the wick. Skin oils can interfere with the cotton's natural absorbency and disrupt uniform moisture uptake.
2. Correct Wrapping Technique: Wind the wick snugly and evenly around the sensor probe, leaving no gaps or loose sections. The lower end of the wick must remain fully submerged in the water reservoir at all times to maintain continuous capillary feed.
3. Scheduled Replacement: For consistent measurement accuracy, replace the wick approximately once per month under normal operating conditions. In environments with higher dust levels or heavier usage, more frequent replacement may be necessary to prevent contamination-related drift.
4. Water Quality Requirements: Always use distilled or deionized water in the reservoir. Tap water contains minerals that can accumulate on the wick over time, leading to hardening, reduced absorbency, and inaccurate humidity readings.
5. Routine Inspection: Periodically check the wick for signs of discoloration, stiffness, or uneven wetting. Any of these indicators suggest the wick should be replaced ahead of the standard monthly schedule.
![]() | ![]() |
FAQs on the Wet Bulb Gauze Wick for Humidity Climate Chambers
Q1: How often should the wet wick be replaced?
Under normal laboratory conditions, the LIB Industry wet wick should be replaced approximately once per month. Replacement frequency may increase in dusty environments or with hard water use.
Q2: What type of water should be used with the wick?
Distilled or deionized water is strongly recommended to prevent mineral deposits that cause premature hardening and reduced accuracy.
Q3: Can regular medical gauze be used as a substitute?
While medical gauze can absorb water, it lacks the density and hydrophilicity engineered into the LIB Industry wet wick, resulting in less stable and less accurate wet-bulb readings over time.
Q4: Is the wick compatible with all humidity chamber brands?
The standard W43mm width fits most common wet-bulb sensor configurations, though customers should confirm sensor probe dimensions before ordering for full compatibility.